Off-line Filters

FN1_040_72dpi

Off-line Filter FN1 040

 - In-line mounting

 - Operating pressure up to 12 bar / 174 psi

 - Nominal flow rate 40 l/min / 10.6 gpm


Application

Return-flow filter or off-line filter in hydraulic and lubrication systems.

Performance features
The EXAPOR®MAX 2 and EXAPOR®AQUA ultra-fine elements are the heart of the ARGO-HYTOS off-line filters. High separation efficiencies guarantee excellent cleanliness levels and thereby the highest protection of components. The high dirt and water capacity of the EXAPOR®MAX 2 and EXAPOR®AQUA elements allow economic operation of the machine.

Model Number Q nom. l/min (GPM) P max. bar (PSI) Connection Data Sheet Need More Information?
FN1 04040 (10.6)12 (174)-FN1040_8005
Find Out More
FN_060

Off-line Filters FN 060 -
FN 300

 - In-line mounting

 

Application
Main flow filter or off-line filter in hydraulic and lubricating systems.

Performance features
Protection against wear: By means of filter elements that in full-flow filtration, meet even the highest demands regarding cleanliness classes.
Protection against malfunction: Through installation near to the control valves or other expensive components. The specific determined flow rate guarantees a closed by-pass valve even at ν ≤ 200 mm²/s (cold start condition).

Model Number Q nom. l/min (GPM) P max. bar (PSI) Connection Data Sheet Need More Information?
FN 060115 (30.4)12 (174)G1FN060_8010
Find Out More
FN 300650 (171.7)10 (145)SAE 2½FN300_8010
Find Out More
FNS-040_72dpi

Off-line Filter With Water Absorbing Element
FNS 040

 - Nominal flow rate approx. 6 l/min

 - Operating pressure up to 320 bar

 - Water capacity approx. 350 ml


The FNS 040-105 is used to filter permanently solid particles as well as water from hydraulic oil. The clogging of the filter element is displayed by means of a manometer.

Through a flow control valve the FNS off-line filter can be connected to a high pressure pipe with an inlet pressure of up to 320 bar (minimum inlet pressure approx. 20 bar). The flow rate is kept constant at approx. 6 l/min depending on the inlet pressure.

Model Number Q nom. l/min (GPM) P max. bar (PSI) Connection Data Sheet Need More Information?
FNS 0406 (1.6)320 (4641)G1FNS040_802
Find Out More
FNS060_mitSchatten_150dpi

Off-line Filter FNS 060

 - With flow control valve

 - Operating pressure up to 320 bar (4640 psi)

 - Nominal flow rate up to 4 l/min (1.06 gpm)


Application

In the high pressure circuits of hydraulic and lubricating oil systems.

Performance features
Protection against wear: By means of ultra-fine filter elements that meet even the highest demands regarding cleanliness classes and dirt-holding capacity.
Protection against malfunction: By means of permanent filtration in the off-line circuits excellent cleanliness classes can be achieved.

Model Number Q nom. l/min (GPM) P max. bar (PSI) Connection Data Sheet Need More Information?
FNS 0604 (1.1)320 (4641)G1 / G1FNS060_8020
Find Out More
FNA_014_72dpi

Off-line Filter Unit With DC Motor FNA 014

 - Version with 24 VDC electric motor

 - Nominal flow rate 14 l/min

 - Operating pressure up to 4bar

 - Efficient filter elements 3, 5 or 10 µm

 - Optionally with dewatering filter element


Application

Off-line filtration in hydraulic and lubricating oil systems.

Performance features
Protection against wear: By means of filter elements that meet even the highest demands regarding cleanliness classes and dirt-holding capacity.
Protection against malfunction: By means of permanent filtration in the off-line circuits excellent cleanliness classes can be achieved.
This can lead to significantly longer intervals between maintenance work and oil changes, as well as reduction of machine failures due to contamination.

Model Number Q nom. l/min (GPM) P max. bar (PSI) Connection Data Sheet Need More Information?
FNA 01414 (3.7)4 (58)-FNA014_8035
Find Out More
FNA_008_mit_Fliess_Web

Off-line Filter Units
FNA1 008 - FNA1 016

 - Operating pressure up to 4 bar (58 psi)

 - For tank capacities up to 1.500 l


Application

Off-line filtration in hydraulic and lubricating oil systems.

Performance features
Protection against wear: By means of filter elements that meet even the highest demands regarding cleanliness classes and dirt-holding capacity.
Protection against malfunction: By means of permanent filtration in the off-line circuits excellent cleanliness classes can be achieved.
This can lead to significantly longer intervals between maintenance work and oil changes, as well as reduction of machine failures due to contamination.

 

Model Number Q nom. l/min (GPM) P max. bar (PSI) Connection Data Sheet Need More Information?
FNA1 00810 (2.6)4 (58)G¾ / G½FNA1008_8040
Find Out More
FNA1 01619 (5)4 (58)1 1/16-12UN2B/3/4-16UN-2BFNA1016_8040
Find Out More
FNA1HV_008_016_72dpi

Off-line Filter Units With Increased Viscosity Range FNA1HV 008 - FNA1HV 016

 - Operating pressure up to 6 bar / 87 psi

 - Viscosity range 15-1500 mm2/s / 70-6950 SUS


Application

In the by-pass flow of hydraulic and lubrication systems.

Performance features
Protection against wear:
By means of filter elements that meet the highest demands regarding cleanliness class and dirt-holding capacity.


Protection against failure
By means of continuous partial filtration, excellent cleanliness classes can be achieved. Machine failures, due to contamination, are reduced, maintenance and oil change intervals are extended.

Model Number Q nom. l/min (GPM) P max. bar (PSI) Connection Data Sheet Need More Information?
FNA1HV 0088 (2.1)6 (87)-FNA1HV008_8041
Find Out More
FNA1HV 01616 (4.2)6 (87)-FNA1HV016_8041
Find Out More
FNA_040_72dpi

Off-line Filter Unit
FNA 040-553

 - Nominal flow rate up to 40 l/min (10.6 gpm)

 - Operating pressure up to 8 bar (116 psi)

 - For tank volumes up to 5.000 l


The FNA 040-553 can be used as an additional off-line filter unit or as a sole system filter for continuous improvement of the oil cleanliness. Operation of the unit is independant of the working cycles of the machine. Thereby the filter element can be changed without interrupting the working process.

Model Number Q nom. l/min (GPM) P max. bar (PSI) Connection Data Sheet Need More Information?
FNA 040-55340 (10.6)8 (116)-FNA 040_8045
Find Out More
FNA045_150dpi

Off-line Filter Unit
FNA 045

 - Operating pressure up to 7 bar (101 psi)

 - Nominal flow rate up to 45 l/min (12 gpm)

 - For tank capacities up to 5.000 l (1.300 gl)


Application

In the off-line circuits of hydraulic and lubricating oil systems.

Performance features
Protection against wear: By means of filter elements that, meet even the highest demands regarding cleanliness classes and dirt-holding capacity.
Protection against malfunction: By means of permanent filtration in the off-line circuits excellent cleanliness classes can be achieved.
This can lead to significantly longer intervals between maintenance work and oil changes, as well as reducing machine failure due to contamination.

Model Number Q nom. l/min (GPM) P max. bar (PSI) Connection Data Sheet Need More Information?
FNA 04545 (11.9)7 (102)G 1¼/G1FNA045_8050
Find Out More
FNAPC_045_72dpi_web

Off-line Filter Unit With Oil Condition Measurement
FNAPC1 045

 - With oil condition monitoring

 - Nominal flow rate up to 45 l/min / 12 gpm

 - Operating pressure up to 7 bar / 101 psi


Application
In the by-pass flow of hydraulic and lubrication systems.

Model Number Q nom. l/min (GPM) P max. bar (PSI) Connection Data Sheet Need More Information?
FNAPC1 04545 (11.9)7 (102)-FNAPC1045_8051
Find Out More
FNU008_72dpi

Off-line Filter Unit FNU 008

 - Operating pressure up to 4 bar

 - Nominal flow rate up to 8 l/min


Application

Off-line filtration in hydraulic and lubrication oil systems.

 

Performance features
Protection against wear: By means of filter elements that meet even the highest demands regarding cleanliness classes and dirt-holding capacity.
Protection against malfunction: By means of permanent filtration in the off-line circuits excellent cleanliness classes can be achieved. This can lead to significantly longer intervals between maintenance work and oil changes, as well as reduction of machine failures due to contamination.

Model Number Q nom. l/min (GPM) P max. bar (PSI) Connection Data Sheet Need More Information?
FNU 0088 (2.1)4 (58)G1FNU008_8090
Find Out More

Need help with your Hydraulic Filtering Requirements?

Scroll to Top